216 East 29 Street
Our free Chrome extension shows a building's concern level right on StreetEasy, Zillow, Apartments.com, Redfin and other NYC rental listings.
Our free Chrome extension shows a building's concern level right on StreetEasy, Zillow, Apartments.com, Redfin and other NYC rental listings.
Not on the city's tax-lien sale list (2019–2025). The owner has not fallen far enough behind on property tax or water charges to be flagged for a lien sale.
The owner registered 3 stabilized units with New York State for 2023 — of about 54 apartments.
Rent stabilization here may be tied to a tax benefit and can end when the benefit expires.
Registration counts apply to the building, not to unit numbers. To confirm your own apartment, request your rent history from New York State Homes and Community Renewal — it is free and takes a few weeks.
How to request your rent history →No marshal-executed evictions on record for this building. Eviction cases filed in court but not carried out aren't included.
No HPD housing-court cases on record for this building.
These are cases HPD is a party to, mostly tenants suing to force repairs or stop harassment. Eviction cases landlords file against tenants are not in the city's open data, so they don't appear here; the Evictions section shows only evictions a marshal carried out.
These are separate from DOB violations. They are summonses written by DOB inspectors and decided at a hearing before OATH, the city's administrative court (formerly the Environmental Control Board), and they can carry a fine. "Lost by default" means the owner never appeared at the hearing. An unpaid balance is a stronger "ignoring the city" signal than a raw violation count.
How this is set: open hazardous violations measured against the building's size, then raised by strong distress signals — HPD's enforcement program, court harassment findings, recent evictions, unpaid OATH/ECB fines, open housing-court cases, and a sold tax lien. Neighborhood noise and crime are not part of it. It describes the public record, not the condition of any one apartment, and a quiet record is not proof of a good building.
Class C is immediately hazardous, Class B is hazardous, Class A is non-hazardous. A violation stays open until HPD certifies the repair, so some open items may already be fixed. HPD writes a separate violation for each room or spot, so one inspection can produce several near-identical entries; those are grouped below by apartment and date.
SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED STREET ENTRANCE DOOR TO 1 STY VESTIBULE.
Status: Certified late
SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED STREET DOOR TO 1 STY PUBLIC HALL VESTIBULE.
Status: Notice issued, not yet certified
SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES AT PUBLIC HALL, 1st STORY
Status: Notice issued, not yet certified
Status: Notice issued, not yet certified
No other buildings found sharing this building's registered contact.
The owner filed 8 annual bedbug reports and reported no infested units. Filing with zero infestations is the compliant, reassuring case.
Violations issued by the Department of Buildings that the owner must correct. Most don't carry a fine on their own; summonses that go to a hearing and can be fined are listed separately under OATH/ECB.
FAILURE TO MAINTAIN BLDG WALL & APPURTANCES. SPALLED/CRACKED MASONRY BRICKS MULTI LOCS OF PARAPET LVL,OPEN/REMOVED LINTEL BRICKS WITH WOOD BRACING INSTALL IN PLACE @ EXP1N & EXP2E. REMEDY: OWNER TO REPAIR/ REPLACE AND MAINTAIN EXTERIOR WALLS AS PER CODE REQUIRED
FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. OBSERVED CRACKING /SPALLING PORCELAIN BRICK VENEER, MULTI LOCATIONS OF PARAPET LEVEL AT EXPOSURE 1 NORTH ELEVATION.OBSERVED CRACKING/SPALLING PORCELAIN BRICK VENEER, MULTI LOCATIONS AT EXPOSURE 2 EAST ELEVATION. REMEDY: OWNER TO REPAIR AND/OR REPLACE DAMAGED EXTERIOR BUILDING WALLS
PROVIDE EXTENTION APPX 15" LINEAR FEET OF SIDEWALK SHED @ EXPO#2 NORTH EASTERN CORNER ELEVATION
Complaints record what a tenant reported, not a finding by the city. "Closed" often means the inspector could not gain access.
NYPD complaints reported within about 1,000 ft (a few blocks) in the last year, by severity. This reflects what gets reported and where police are active as much as actual safety, and busier, denser, higher-foot-traffic blocks log more. Locations are approximate — the NYPD shifts each report to the nearest corner for privacy — so read this as rough context, not a safety score.
From ACRIS recorded documents. Amounts are often $0 or nominal for transfers between related parties, and LLCs can obscure who is really involved — treat this as public-record context, not a valuation.
311 noise complaints within about 1,000 ft (a few blocks) in the last year. Most reports here are about noise from inside buildings — neighbors, not the street. This counts how often people call 311, which tracks how densely populated and busy an area is as much as how loud it is — it is not a sound measurement.